Laboratory Biopharmaceutical Aluminum Alloy Side Liquid Tank High-Efficiency Air Filter

Product Details
Customization: Available
Clapboard: Liquid Trough
Filter Number: Gel
Gold Member Since 2025

Suppliers with verified business licenses

Registered Capital
1000000 RMB
Management System Certification
ISO 9001, GMP
  • Laboratory Biopharmaceutical Aluminum Alloy Side Liquid Tank High-Efficiency Air Filter
  • Laboratory Biopharmaceutical Aluminum Alloy Side Liquid Tank High-Efficiency Air Filter
  • Laboratory Biopharmaceutical Aluminum Alloy Side Liquid Tank High-Efficiency Air Filter
  • Laboratory Biopharmaceutical Aluminum Alloy Side Liquid Tank High-Efficiency Air Filter
  • Laboratory Biopharmaceutical Aluminum Alloy Side Liquid Tank High-Efficiency Air Filter
  • Laboratory Biopharmaceutical Aluminum Alloy Side Liquid Tank High-Efficiency Air Filter
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Features:
  • Installation Instructions
Overview

Basic Info.

Model NO.
YWGB 410.410-93H14
Medium Material
Fiberglass
Efficiency
H14
Filtration Grade
HEPA Filter
Type
Folded Filter
Initial Pressure Drop
220PA
Final Pressure Drop
450PA
Air Flow
500 M3/H
Degree
Max 40ºC
Humidity
Max 100%Rh
Seal
Gel
Filter Media
Glass Fiber
Frame
Aluminum
Filter Fineness
0.3μm
Filter Level
99.995%~99.9995%
Packaging Details
Carton Box
Transport Package
Carton Box
Specification
410× 410× 93mm
Trademark
Licheng
Origin
China
HS Code
8421999090
Production Capacity
5000PCS/Month

Product Description

Laboratory biopharmaceutical aluminum alloy side liquid tank high-efficiency air filter
Product Description

Air filters are widely used in purification systems. Among air filters, there is a type of high-efficiency filter with excellent sealing performance, which is the liquid tank high-efficiency filter. The liquid trough type high-efficiency filter is a device used for filtering impurities in liquids
It is widely used in the liquid treatment process in the industrial field. By installing liquid tank type high-efficiency filters, particles, suspended solids and other impurities in the liquid can be effectively removed, improving the purity and quality of the liquid.
Laboratory Biopharmaceutical Aluminum Alloy Side Liquid Tank High-Efficiency Air Filter

Product Parameters
Model Size(W×H×D) Air Flow
(m3/h)
Initial Pressure Drop(Pa) Final Pressure Drop(Pa) Efficiency
@MPPS
YWGB 410.410-93H14 410×410×93 500 220 450 99.995%≤E   <99.9995%
YWGB 550.550-93H14 550×550×93 1000
YWGB 650.650-93H14 650×650×93 1500
 Laboratory Biopharmaceutical Aluminum Alloy Side Liquid Tank High-Efficiency Air Filter
Features:

 

Laboratory Biopharmaceutical Aluminum Alloy Side Liquid Tank High-Efficiency Air FilterLaboratory Biopharmaceutical Aluminum Alloy Side Liquid Tank High-Efficiency Air FilterLaboratory Biopharmaceutical Aluminum Alloy Side Liquid Tank High-Efficiency Air Filter

Installation Instructions

Before installing the liquid tank high-efficiency filter, it is necessary to prepare the required materials and tools. Usually, it is necessary to prepare the liquid tank high-efficiency filter itself, connecting pipes, as well as tools such as screwdrivers and wrenches.

1. Determine the installation location
First, the installation location of the high-efficiency filter needs to be determined based on the size of the room and the usage conditions. Generally speaking, installation should be carried out in a location that is close to human activity areas, has good ventilation conditions and is not easily blocked. In addition, the sealing performance of the equipment should also be taken into account to prevent outside air from directly entering the interior of the equipment and affecting its normal operation. At the same time, the installation location can also be moderately expanded. For instance, multiple high-efficiency filters can be installed in different corners of the room to enhance the air purification effect. 

2. Install the pretreatment device
The liquid trough type high-efficiency filter needs to be combined with a pretreatment device to exert its effect. The pretreatment device generally includes a primary filter and a medium-efficiency filter, which are used to filter out large particles of dust and impurities and reduce the burden on the high-efficiency filter. Before installing the high-efficiency filter, it is necessary to connect the pretreatment device to the air inlet of the high-efficiency filter first. To achieve a better filtration effect, it is advisable to consider adding more types of filters, such as activated carbon filter elements, to further enhance the air purification effect.

3. Connect the pipes
High-efficiency filters need to be connected to the outside through pipes to achieve air circulation. When installing, the appropriate material and specification of the pipes should be selected, and they should be cut and connected as needed. To ensure the sealing of the pipeline, a sealing gasket or glue can be added at the interface. In addition, during the process of connecting pipelines, valves and other equipment can be added to facilitate the adjustment of the speed and flow rate of air circulation.

4. Install the liquid tank filter
The liquid tank is the core component of the liquid tank type high-efficiency filter and requires special attention during installation. First of all, the liquid tank needs to be placed at the predetermined position to ensure a tight connection with the pipeline. Then, install a high-efficiency filter at the air inlet of the liquid tank to ensure the filtration effect of the air. Then, an appropriate amount of liquid (such as water or oil) needs to be filled into the liquid tank so that the tank can play a role in filtration and purification. After the liquid tank is installed, it is necessary to check whether its sealing is good and conduct a trial run to ensure the normal operation of the equipment. In addition, liquid level sensors and other equipment can be added to monitor the liquid level in the liquid tank and replenish or replace it in a timely manner.

5. Debugging and maintenance
After the high-efficiency filter is installed, it still needs to be debugged and maintained. During the commissioning process, it is necessary to check aspects such as pipeline connections, liquid tank sealing and filtration effects, and make necessary adjustments to the equipment. In terms of maintenance, it is necessary to regularly replace the filter, clean the liquid tank and inspect the pipe connections, etc., to ensure the normal operation of the equipment. In addition, automated monitoring equipment can be added to achieve real-time monitoring of the operating status of high-efficiency filters and fault alarms, thereby enhancing the reliability and maintenance efficiency of the equipment.

The installation process of the liquid tank type high-efficiency filter mentioned above includes multiple steps such as determining the installation location, installing the pretreatment device, connecting the pipeline, installing the liquid tank and commissioning and maintenance. Only by installing it in the correct way can the equipment operate normally and achieve the best filtration and purification effect. Wuxi Licheng specializing in the production of liquid tank type high-efficiency filters, the compact structure of the box body and the liquid tank knife edge ensures higher sealing reliability. Meanwhile, it is also equipped with a PAO test port to verify the reliability of the installation after the filter is replaced. In addition, we offer a variety of side and top pipe styles with different air volumes to meet the diverse installation requirements on site. They are widely used in technical fields such as hospitals, laboratories, biopharmaceuticals, semiconductors, precision machinery, and optics.

 

 

 



 



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier